To change the text size, hold down the Ctrl/Cmd key and press + to enlarge or - to reduce

Sitemap LinkedIn
PETROLEUM TECHNOLOGY COMPANY
- Improving well performance and integrity
Solutions

About Wellhead Solutions

VR Lubricator Tool
VR Lubricator Tool
Master Surface Annulus Safety Valve
MSAS-G (integrated in API gate valve)
VR P&T Sensor Wired
VR P&T Sensor Wireless
VR P&T Sensor Exit Block Wired

Solutions for wellhead integrity challenges today.

 

Well integrity assurance is a fundamental need throughout the lifecycle of all wells. Definitions vary, but the universally adopted rule to facilitate this is:

 

“At least two tested independent (primary and secondary) barriers between a hydrocarbon source and the environment shall exist at all times”

 

 

Well Integrity Management

It has been reported that Sustained Annulus Pressure (SAP) is a challenge in over 40%  of today’s global well stock. Many wells are prematurely shut in as a result

 

Most commonly the SAP is un-planned,  and a result of down-hole completion, casing or cementation failure. In other cases, where lift gas is being injected or vent gas is being produced via the annulus, the SAP is planned. Irrespective, both scenarios pose a significant risk to personnel and facilities as the double barrier rule has been compromised in these wells. Specifically, the annulus line gate valves, ring gaskets, instrument flanges and pressure gauges provide only a single barrier between the hydrocarbon source and the environment.

 

Continuous monitoring of  the annulus with SAP and its outer counterpart is critical for safe operations. A method  for the safe management and bleed off of pressure in the event that it approaches the casing or tubing design limits is also necessary.

 

Historically there was no optimum solution to these challenges. PTC have now developed unique technologies, which fully address the issues. These are now field proven and increasingly adopted by OPCO’s worldwide.

 

 

Annulus Pressure Monitoring

Continuous annulus pressure and temperature (P&T) monitoring, with enhanced well integrity using PTC’s unique VR Sensor system. The system eliminates the need for wellhead gate valves and instrument flanges. It is also designed to maintain well integrity even upon impact or collision.

 

 

Annulus Pressure Management

PTC’s Master Surface Annulus Safety Valve (MSAS) is installed in the wellhead VR profile. It can be used as an actuated (fail-safe closed) barrier valve in gas lift applications, or safety / bleed valve in wells where SAP or annulus production needs to be managed.

 

 

Autonomous Annulus Pressure Management

The integration of PTC's  VR sensor, Master Surface Annulus Safety Valve and Hydraulic Control & Power Unit provides a system for autonomous and controlled annulus pressure management. The system, called A-Pro,  can be configured to both autonomous and human intervention modes. The system can be self-sustained or connected to an external power source.